FA700KP-ADS Installation and Setup Guide
2–4
6270-002-V1
DATA OUT (YELLOW)
GROUND (BLACK)
DATA IN (GREEN)
+12VDC (RED)
G
Y
+
+
+
+
+
Figure 3. Wiring the
FA700KP-ADS
3. Connect the AUX – terminal of the control panel to the (–)
terminal of the supplementary power supply (black wire).
4. Connect the (–) terminal of the supplementary power supply to
terminal block position 3 (GND terminal of the FA700KP-ADS
(black wire)).
5. Connect Data Out terminal of the control panel to terminal block
position 1 (Data In terminal of the FA700KP-ADS (yellow wire)).
6. Connect the Data In terminal of the control panel to header
terminal block position 4 (Data Out terminal of the FA700KP-
ADS (green wire)).
7. Attach the case front of the FA700KP-ADS to the case back.
Attach the top of the case first, and then press the bottom section
inward until it snaps into place securely.